Fuel
oil meters with mechanical roller counter. Versions
with threaded or flanged connections as well as reed
contactor RV or inductive pulser IN (NAMUR IEC 60947-5-6). |
| |
|
Display
in liters, wide measuring range with max permissible
error of ±0.5% of reading. For special applications
such as: |
 |
Differential measurement |
 |
Charging purposes with
verified counters |
 |
Measurement to bench
performance and wherever high accuracy is required. |
| |
|
| Your
benefits... |
 |
The optimum solution
for differential measurement with minimum tolerance using
paired calibration. |
 |
High operational safety
due to vibration resistance. |
 |
Space saving installation
without requirement of straight inlet or outlet paths. |
 |
Easy to
install without restriction either horizontally, vertically
or inclined. |
| |
 |
High operational safety
due to integral safety filter in the meter inlet. Reduces
effort on start-up. |
| |
|
|
| |
Meters
for heavy fuel oil should have a nominal diameter of
DN 20 or larger. |
| |
|
|
| Type designation key |
| |
 |
| |
| |
| Threaded connection, temperature
max 130 °C, nominal pressure 16 bar |
| |
| Nominal diameter
(mm) |
DN 15 |
DN 20 |
DN 25 |
DN 40 |
DN 50 |
|
| Continuous flow rate Qn (l/h) |
400 |
1'000 |
2'000 |
6'000 |
20'000 |
| Type of counter, nominal diameter |
VZOA 15.. |
VZOA 20.. |
VZOA 25.. |
VZOA 40.. |
VZOA 50.. |
|
| Connection,
temperature, nominal pressure |
|
| Standard |
92286 |
92290 |
92293 |
92296 |
- |
..RC130/16 |
|
With reed
contactor
0.1 l/pulse |
92287 |
- |
- |
- |
- |
..RC130/16 |
RV0,1 |
With reed
contactor
1 l/pulse |
92288 |
92291 |
92294 |
92297 |
- |
..RC130/16 |
RV1 |
With inductive
pulser
0.01 l/pulse |
92289 |
92292 |
- |
- |
- |
..RC130/16 |
IN0,01 |
With inductive
pulser
0.1 l/pulse |
- |
- |
92295 |
92298 |
- |
..RC130/16 |
IN0,1 |
| Pulser,
pulse value |
|
| |
| Flanged connection, temperature
max 130 °C, nominal pressure 25 bar |
| |
| Nominal diameter
(mm) |
DN 15 |
DN 20 |
DN 25 |
DN 40 |
DN 50 |
|
| Continuous flow rate Qn (l/h) |
400 |
1'000 |
2'000 |
6'000 |
20'000 |
| Type of counter, nominal diameter |
VZOA 15.. |
VZOA 20.. |
VZOA 25.. |
VZOA 40.. |
VZOA 50.. |
|
| Connection,
temperature, nominal pressure |
|
Standard |
92299 |
92303 |
92306 |
92309 |
92312 |
..FL130/25 |
|
With
reed contactor
0.1 l/pulse |
92300 |
- |
- |
- |
- |
..FL130/25 |
RV0,1 |
With
reed contactor
1 l/pulse |
92301 |
92304 |
92307 |
92310 |
- |
..FL130/25 |
RV1 |
With
reed contactor
10 l/pulse |
- |
- |
- |
- |
92313 |
..FL130/25 |
RV10 |
With
inductive pulser
0.01 l/pulse |
92302 |
92305 |
- |
- |
- |
..FL130/25 |
IN0,01 |
With
inductive pulser
0.1 l/pulse |
- |
- |
92308 |
92311 |
- |
..FL130/25 |
IN0,1 |
With
inductive pulser
1 l/pulse |
- |
- |
- |
- |
92314 |
..FL130/25 |
IN1 |
| Pulser,
pulse value |
|
| |
Flanged connection, temperature
max 180 °C, nominal pressure 25 bar |
| |
| Nominal diameter
(mm) |
DN 15 |
DN 20 |
DN 25 |
DN 40 |
DN 50 |
|
| Continuous flow rate Qn (l/h) |
400 |
1'000 |
2'000 |
6'000 |
20'000 |
| Type of counter, nominal diameter |
VZOA 15.. |
VZOA 20.. |
VZOA 25.. |
VZOA 40.. |
VZOA 50.. |
|
| Connection,
temperature, nominal pressure |
|
Standard |
92315 |
92319 |
92322 |
92325 |
92328 |
..FL180/25 |
|
With
reed contactor
0.1 l/pulse |
92316 |
- |
- |
- |
- |
..FL180/25 |
RV0,1 |
With
reed contactor
1 l/pulse |
92317 |
92320 |
92323 |
92326 |
- |
..FL180/25 |
RV1 |
With
reed contactor
10 l/pulse |
- |
- |
- |
- |
92329 |
..FL180/25 |
RV10 |
With
inductive pulser
0.01 l/pulse |
92318 |
92321 |
- |
- |
- |
..FL180/25 |
IN0,01 |
With
inductive pulser
0.1 l/pulse |
- |
- |
92324 |
92327 |
- |
..FL180/25 |
IN0,1 |
With
inductive pulser
1 l/pulse |
- |
- |
- |
- |
92330 |
..FL180/25 |
IN1 |
| Pulser,
pulse value |
|
| |
| Options |
| |
| Modification |
Order No. |
| Cable
mounted (to pulser IN) |
80019 |
| Paired
for differential measurement |
96112 |
| Type
approval for ships (e.g. GL, LRS, DNV) |
96295 |
| EEC
Type approval with legal verification
1) |
96026 |
| PTB
type approval 1) 2) |
|
|
1)
Please observe the reduced measuring ranges with this
option. It does not allow combination with option "Paired
for differential measurement".
2) under Germany law. |
| |
Accessories |
| |
| Product |
Type
|
Version |
Order No. |
| Threaded
connections |
VSR 1/2" |
DN 15 |
81160 |
| VSR 3/4" |
DN 20 |
81166 |
| VSR 3/4" x 1/2" |
DN 20 |
81163 |
| VSR 1" |
DN 25 |
81169 |
| VSR 1 1/2" |
DN 40 |
81181 |
|
| |
| Ancillaries |
| |
Product |
Type |
Version |
Order
No. |
| Remote
totalizer |
Pulse counter |
Pulse counter,
selectable reset/non-reset |
93374 |
| Transmitter |
Isolated switch
amplifier |
Relay output,
max. 10 Hz |
81705 |
With electronic
output, 5 kHz |
80013 |
|
| |
Ancillaries with mounting
accessories |
| |
| Product designation |
Type
|
Version |
Order No. |
| Transmitter |
Flow computer |
Freely programmable,
with analogue output 4…20 mA, instantaneous
flow rate |
92439 |
Differential
totalizer / flow computer |
Freely programmable,
with analogue output 4…20 mA, instantaneous
flow rate, both inputs can be read separately |
92440 |
Frequency-current
converter |
Freely programmable |
92439 |
| Mounting
accessories |
Mounting set |
For wall or DIN-rail (35
mm) mounting |
80082 |
|