Products for oil   deutschfrancaisenglishcesky
      chinesekoreanjapanese
  Ships/Boats > Differential measurement            
 

Meters for heavy fuel oil should have a nominal diameter of DN 20 or larger.

  For optimum differential measurement, two meters with the "paired calibration" option are recommended. Please note the specifications given in the CONTOIL® Technical Information brochure.
  Type approval for ships (e.g. GL, LRS, DNV) as option
                 
  Max. Tempe-
rature of fuel
°C
Max. flow
rate
approx.
Max. permissible error Counter Signal outputs Option To the product
<click icon>
 
  130 °C 20'000 l/h ± 0.5% of reading electronic
counter

volumetric pulses
flow rate
limit switches

Calibrated in pairs  
 
  130 °C 20'000 l/h ± 0.5% of reading mechanical
roller counter

volumetric pulses
(optional) 1)

Calibrated in pairs  
 
  180 °C 20'000 l/h ± 0.5% of reading electronic
counter
volumetric pulses
flow rate
limit switches
Calibrated in pairs  
 
  180 °C 20'000 l/h ± 0.5% of reading mechanical
roller counter

volumetric pulses
(optional) 1)

Calibrated in pairs  
   
  1) Reed pulser should not be used as it is sensitive to vibration.

 